GH-900Plus

Lifotronic fully automated GH-900Plus HbA1c Analyzer supports fast HbA1c results output in 130 seconds without Hb variant interference, 5 sample loading. It provides the outstanding solution for reliable diabetic monitoring. No sample preparation and walk-away operation. High-Pressure Liquid  chromatography (HPLC), to separate HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbA1c testing result, excluding interference of variant and unstable hemoglobin like LA1c. Standard Analysis Mode will report HbA1a, HbA1b, HbF, LA1c, HbA1c, HbA0 peak areas and percentage. And the result also includes IFCC, NGSP and ADAG value for diverse client needs.

Share:
Get a Quote Download Brochure Lifotronic
Keywords :
GH-900Plus

Technical Specification

Details

Methodology

High Performance Liquid Chromatography (HPLC)

Test Modes

Variant Mode

Test Range

3% ~ 20%

Precision

CV < 1.0%

Test Speed

Variant Mode: 58s

Reagent Kit

Eluent A: 800mL, 1600mL; Eluent B: 800mL; Eluent C: 800mL; Eluent D: 800mL, 1600mL; Hemolytic Agent L: 2500mL, 5000mL

Sample Volume

5 uL

Hemoglobin Interferences

No interference from variants E, D, S, C, J; No interference from HbF up to 15%

Sample Rack

Normal Sample Rack, Anemia Sample Rack, QC Rack, Calibrator Rack

Sample Positions

110 Positions + 1 STAT Position

Display

10.1" TFT True Color LCD Touch Screen

Data Storage

20,000 Sample Results

Connection

RS232, USB, LIS Compatible

Barcode Scanner

Internal Barcode Scanner or Handheld Barcode Scanner

Printer

Internal Thermal Printer and External Laser Printer

Temperature

Storage: 0°C ~ 55°C; Operating: 10°C ~ 30°C

Humidity

Storage: ≤93%; Operating: ≤80% (non-condensing)

Dimensions

722mm (L) x 675mm (W) x 732mm (H)

Weight

62KG

Lifotronic fully automated GH-900Plus HbA1c Analyzer supports fast HbA1c results output in 130 seconds without Hb variant interference, 5 sample loading. It provides the outstanding solution for reliable diabetic monitoring. No sample preparation and walk-away operation. High-Pressure Liquid  chromatography (HPLC), to separate HbA1c directly with measuring the absorbance points continually to form chromatogram. Using normal distribution curve fitting auto-iterative algorithm to get precise HbA1c testing result, excluding interference of variant and unstable hemoglobin like LA1c. Standard Analysis Mode will report HbA1a, HbA1b, HbF, LA1c, HbA1c, HbA0 peak areas and percentage. And the result also includes IFCC, NGSP and ADAG value for diverse client needs.